Availability
|
| Modular design
|
Provides fast serviceability and reduced
maintenance requirements via self-diagnosing, field-replaceable
modules. |
| Configurable for
N+1 internal redundancy |
Provides high availabilty through redundancy
by allowing configuration with one more Power Module
than is necessary to support the connected load.
|
| Redundant Intelligence
Modules |
Provides higher availability to the
UPS connected loads by giving redundant communication
paths to critical UPS functions. |
| Hot-swappable intelligence
modules |
Ensures clean, uninterrupted power
to protected equipment during Intelligence Module replacement.
|
| Hot-swappable power
modules |
Ensures clean, uninterrupted power
to protected equipment during Power Module replacement.
|
| Hot-swappable batteries
|
Ensures clean, uninterrupted power
to protected equipment while batteries are being replaced
|
| Power Modules connected
in parallel |
Enhances availability by allowing immediate,
seamless recovery from isolated module failures.
|
| Battery modules connected
in parallel |
Delivers higher availability through
redundant batteries. |
| Automatic internal
bypass |
Supplies utility power to the connected
loads in the event of a UPS overload condition or fault.
|
| Automatic restart
of loads after UPS shutdown |
Automatically starts up the connected
equipment upon the return of utility power. |
|
Scalability
|
| Scalable power capacity
|
Reduces UPS over-sizing costs today
by allowing quick upgrades later. |
| Scalable runtime
|
Allows additional run time to be quickly
added as needed. |
| Plug-and-Play external
batteries |
Ensures clean, uninterrupted power
to the loads when adding extra runtime to the UPS.
|
| Field-replaceable
power distribution panel |
Ensures compatibility with equipment
that has different plug types. |
| Programmable frequency
|
Ensures compatibility with different
input frequencies. |
|
Manageability
|
| Manageable external
batteries |
Reduces preventative maintenance service
needs by monitoring the health and status of the external
batteries and their expected runtime. |
| Network manageable
|
Provides remote management of the UPS
over the network. |
| InfraStruXure Manager
compatible |
Enables centralized management via
the APC InfraStruXure® Manager. |
| LCD display |
Alpha-Numeric Display which displays
system parameters and alarms. |
| Intelligent battery
management |
Maximizes battery performance, life,
and reliability through intelligent, precision charging.
|
| SmartSlot |
Customize UPS capabilities with management
cards. |
|
Serviceability
|
| Predictive failure
notification |
Provides early-warning fault analysis
ensuring proactive component replacement. |
| Automatic self-test |
Periodic battery self-test ensures
early detection of a battery that needs to be replaced.
|
| Audible alarms
|
Actively let you know if the unit is
on battery, if the battery is low or if there is an
overload condition. |
| User-replaceable
intelligence modules |
Enables simple upgrades and replacements
of the Intelligence Modules. |
| User-replaceable
power modules |
Enables simple upgrades and replacements
of the Power Modules. |
| User-replaceable
batteries |
Increases availability by allowing
a trained user to perform upgrades and replacements
of the batteries reducing Mean Time to Repair (MTTR)
|
| Disconnected battery
notification |
Warns when a battery is not available
to provide backup power. |
|
Protection
|
| Power conditioning
|
Protects connected loads from surges,
spikes, lightning, and other power disturbances.
|
| Frequency and voltage
regulation |
Gives higher application availability
by correcting poor frequency and voltage conditions
without using the battery. |
| Input power factor
correction |
Minimizes installation costs by enabling
the use of smaller generators and cabling. |
| Generator compatible
|
Ensures clean, uninterrupted power
to the loads in the event of an extended power outage
; |
| Cold-start capable
|
Provides temporary battery power when
the utility power is out. |
| Resettable circuit
breakers |
Enables a quick recovery from overload
events. |
| Safety-agency approved
|
Ensures the product has been tested
and approved to work safely with the connected service
provider equipment and within the specified environment.
UL, FCC, CE, C-Tick approvals. |